Vent Installation

V

enting

:

The Vintage™ gas stove has been tested and listed as a direct-vent

heater system by OMNI-Test Laboratories, Portland, Oregon and

is recommended for use with Security™ Secure Vent pipe*.
Important:

• Read all instructions carefully before starting the installation.

Failure to follow these instructions may create a fire or other
safety hazard and will void the warranty. Be sure to check for
specific clearances to combustible requirements on Page 8.
Do not extend the venting system vertically or horizontally in
excess of the distance prescribed on Page 15
. Consult your
local building codes before beginning the installation.

Always maintain the proper air spaces between the vent pipe

and nearby combustibles to prevent a fire hazard. Do not fill
air spaces with insulation. Be sure to check the vent termina-
tion clearance requirements from decks, windows, soffits, gas
regulators, air supply inlets and public walkways, as specified
in these installation instructions on Page 16 and local building
codes.

This gas appliance and vent system must be vented directly

to the outside of the building and never be attached to a
chimney serving a separate solid fuel or gas-burning appli-
ance
. Each direct-vent gas appliance must use its own separate
vent system. Common vent systems are prohibited.

• The Vintage is recommended for use with Security™ Secure

Vent pipe*. The appliances and vent manufacturers warranties
will be voided and serious fire, health, or other safety hazards
may result from any of the following actions:

- Installation of any damaged direct-vent component.
- Unauthorized modification of the direct-vent system.
- Installation of any vent component part not approved or

manufactured by the approved vent manufacturer.

- Installation other than as instructed by Lennox Hearth

Products and vent manufacturers instructions.

Residential and Mobile Home Installations:

These are the minimum pieces required. Other parts may be required for
your particular installation.

Minimum Components for Horizontal Installation:

Horizontal Termination Kit which includes:

• 1 6-5/8”x 6” Black Pipe
• 1 Riser Vent Terminal
• 1 Wall Penetration Heat Shield (Wall Thimble) (2 pcs)
• 1 Decorative Wall Trim (black)
• 1 Tube Mill-Pac
• Screws

Optional Components:

• 45º Elbow
• Vinyl Siding Shield for Riser Vent Terminal
• Vent Guard
• Snorkel Termination (36”)
• Snorkel Termination (14”)
• Wall Penetration Heat Shield

Vent Considerations:

Twist-lock procedure:

Four indentations on female ends of pipes and

fittings are designed to slide straight onto male ends of adjacent pipes
and fittings by orienting the four pipe indentations so they match and
slide into the four entry slots. Push pipe sections completely together,
then twist-lock one section clockwise approximately one-quarter turn
until the two sections are fully locked. The female locking lugs will not
be visible from the outside on the pipe or fittings. They may be located
by examining the inside of the female ends.

Supports:

Horizontal runs of vent must be supported every 3 feet. Wall

straps are available for this purpose.

Pipe Sealing:

If Simpson Dura-Vent pipe is used, the pipe must be sealed

as follows: seal both the inner and outer pipes with a high temperature
silicone sealant rated for at least 600ºF (commonly know as “RTV”). Run
a 1/8” bead of silicone around outside of male end of outer sleeve. Run
a 1/8” bead of silicone about 1/4” from the end of the male inner pipe,
which is found in the pipe to be attached above. Twist-lock the pipes or
fittings together.

* Other approved chimney brand is Simpson Dura-Vent DV-GS.

Figure 19

Sealant

Female

Locking

Lugs

Male

Locking

Lugs