CLEANING AND MAINTENANCE SCHEDULE

Maintaining a clean UltraGrate™ is vital to the safe and efficient operation of the stove. It is a good idea to verify

your UltraGrate is clean prior to ignition each time you operate your stove.

DAMPER ADJUSTMENT

The Montage™ pellet stove is equipped with a damper which is used to fine tune combustion. Although every

unit is test burned and calibrated at the factory, periodic adjustment may be necessary at times to compensate for

variables such as fuel, venting, altitude, and maintenance intervals.

4

5

IMPORTANT NOTE:

UNPLUG POWER CORD AND ENSURE APPLIANCE IS COLD BEFORE PERFORMING ANY MAINTENANCE WORK.

Above is an example of a pellet

“clinker”. This mass of impurities

can reduce airflow through the

UltraGrate and create an unsafe

burning condition.

Properly cleaned UltraGrate: The

bars running across the bottom are

clean and all the openings are clear.

Dirty UltraGrate: The bars run-

ning across the bottom are not

completely visible. The UltraGrate

should be cleaned.

Opening the damper increases the amount of

combustion air. This can help increase pellet activity

in the UltraGrate™ and correct a dark orange or sooty

flame.

OPENING THE DAMPER

CLOSING THE DAMPER
Closing the damper decreases the amount of

combustion air. This can be a useful adjustment if your

stove is burning out. If the damper is closed too much,

your stove will burn less efficiently and require more

maintenance.

The damper is located behind the right

side door.

REFER TO THE “INSTALLATION AND OPERATION

MANUAL” FOR DETAILED INSTRUCTIONS ON MAKING

ADJUSTMENTS TO THE DAMPER.