Table

1.

Numeric

error

codes

(continued)

Symptom

or

error

FRU

or

action,

in

sequence

0232
Extended

RAM

error—

Extended

RAM

fails

at

offset

nnnn.

1.

DIMM.

2.

System

board.

0250
System

battery

error—System

battery

is

dead.

1.

Charge

the

backup

battery

for

more

than

8

hours

by

connecting

the

ac

adapter.

2.

Replace

the

backup

battery

and

run

BIOS

Setup

Utility

to

reset

the

time

and

date.

0251
System

CMOS

checksum

bad—

Default

configuration

used.

1.

Charge

the

backup

battery

for

more

than

8

hours

by

connecting

the

ac

adapter.

2.

Replace

the

backup

battery

and

run

BIOS

Setup

Utility

to

reset

the

time

and

date.

0260
System

timer

error.

1.

Charge

the

backup

battery

for

more

than

8

hours

by

connecting

the

ac

adapter.

2.

Replace

the

backup

battery

and

run

BIOS

Setup

Utility

to

reset

the

time

and

date.

3.

System

board.

0270
Real-time

clock

error.

1.

Charge

the

backup

battery

for

more

than

8

hours

by

connecting

the

ac

adapter.

2.

Replace

the

backup

battery

and

run

BIOS

Setup

Utility

to

reset

the

time

and

date.

3.

System

board.

0280
Previous

boot

incomplete—

Default

configuration

used.

1.

Load

“Setup

Default”

in

BIOS

Setup

Utility.

2.

DIMM.

3.

System

board.

02F4
EISA

CMOS

not

writable.

1.

Load

Setup

Defaults

in

BIOS

Setup

Utility.

2.

Replace

the

backup

battery.

3.

System

board.

02F5
DMA

test

failed.

1.

DIMM.

2.

System

board.

02F6
Software

NMI

failed

1.

DIMM.

2.

System

board.

02F7
Fail-safe

timer

NMI

failed

1.

DIMM.

2.

System

board.

Related

service

information

37

Advertising