Lennox Hearth CI2500DVF User Manual

Page 3

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

3

HI

L O W

TPTH

TP

TH

PILO

T

PIL

O

T

ON

it

OF

F

HI / LO Knob

Variable Flame Height Adjustment

Manifold Pressure Port

Inlet
Pressure
Port

Main Gas

Control Knob

Piezo Igniter

IN

OUT

CARBON MONOXIDE POISONING: EARLY
SIGNS OF CARBON MONOXIDE POISONING
ARE SIMILAR TO THE FLU WITH HEADACHES,
DIZZINESS AND/OR NAUSEA. IF YOU HAVE
THESE SIGNS, OBTAIN FRESH AIR IMMEDI-
ATELY. TURN OFF THE GAS SUPPLY TO THE
APPLIANCE AND HAVE IT SERVICED BY A
QUALIFIED PROFESSIONAL, AS IT MAY NOT
BE OPERATING CORRECTLY.

Do not use these appliances if any part has
been under water. Immediately call a qualifi ed,
professional service technician to inspect
the appliance and to replace any parts of the
control system and any gas controls which
have been under water.

Ne pas se servir de cet appareil s'il a été
plongé dans l'eau, complètement ou en
partie. Appeler un technicien qualifi é pour
inspecter l'appareil et remplacer toute partie
du système de contrôle et toute commande
qui ont été plongés dans l'leau.

Test gage connections are provided on
the front of the millivolt gas control valve
(identifi ed IN for the inlet and OUT for the
manifold side).

These appliances must be isolated from the
gas supply piping system (by closing their
individual manual shut-off valve) during any
pressure testing of the gas supply piping
system at test pressures equal to or less
than 1/2 psig (3.5 kPa).

These appliances and their individual shut-off
valves must be disconnected from the gas
supply piping system during any pressure
testing of that system at pressures in excess
of 1/2 psig (3.5 kPa).

These appliances must not be connected to a
chimney or fl ue serving a separate solid fuel
burning appliance.

Control Compartment Access

The gas controls can be found behind the lower
access door. To access, pull the door open
(see Figure 2).

Millivolt appliances will be fi tted with the gas
control valve shown in Figure 3. Familiarize
yourself with the gas control valve that your
appliance uses.

OPERATION AND CARE OF YOUR
APPLIANCE

Appliance operation may be controlled through
a remotely located optional wall thermostat or
remote control.

In lieu of remote or remote wall thermostat
operation, the appliance must be operated
directly through the on/off rocker switch located
on the upper right side of the rear shield. See
Figure 1.

If your millivolt appliance is equipped with an
optional wall thermostat kit or remote control
kit and the pilot is lit, the appliance main burner
may be turned on and off with the wall thermostat
or remote control.

WARNING: DO NOT PLACE CLOTHING OR
OTHER FLAMMABLE MATERIALS ON OR
NEAR THIS APPLIANCE.

AVERTISSEMENT: SURVEILLER LES
ENFANTS. GARDER LES VÊTEMENTS,
LES MEUBLES, L'ESSENCE OU AUTRES
LIQUIDES À VAPEUR INFLAMMABLES
LOIN DE L'APPAREIL.

WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE HAZARDS
OF HIGH SURFACE TEMPERATURES. USE
CAUTION AROUND THE APPLIANCE TO
AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CAREFULLY
SUPERVISED WHEN THEY ARE IN THE SAME
ROOM AS THE APPLIANCE.

WARNING: FAILURE TO COMPLY WITH THE
INSTALLATION AND OPERATING INSTRUC-
TIONS PROVIDED IN THIS DOCUMENT WILL
RESULT IN AN IMPROPERLY INSTALLED
AND OPERATING APPLIANCE, VOIDING ITS
WARRANTY. ANY CHANGE TO THIS APPLI-
ANCE AND/OR ITS OPERATING CONTROLS
IS DANGEROUS. IMPROPER INSTALLATION
OR USE OF THIS APPLIANCE CAN CAUSE
SERIOUS INJURY OR DEATH FROM FIRE,
BURNS, EXPLOSION OR CARBON MONOX-
IDE POISONING.

Figure 3

SIT Millivolt Gas Valve Controls

Burner

On /Off

Switch

Top View

Front

Figure 1

Tables 3 and 4 show the units' gas pressure
requirements

Burner On/Off Switch

Gas Controls

Lower Access Door

Pull open lower door to access Valve Contols

Lower Access

Door

Figure 2

Always keep the appliance area clear and free
from combustible materials, gasoline and other
fl ammable liquids.

Remember, Millivolt appliances have a continu-
ous burning pilot fl ame. Exercise caution when
using products with combustible vapors.

Inlet Gas Supply Pressure

(all models)

Fuel #

Minimum

Maximum

Natural Gas

4.5" WC

(1.12 kPa)

10.5" WC

(2.61 kPa)

Propane

11.0" WC

(2.73 kPa)

13.0" WC

(3.23 kPa)

Table 3

Manifold Gas Supply Pressure

(millivolt models)

Fuel #

Low

High

Natural

Gas

(Lo) 1.6" WC

(.40 kPa)

(Hi) 3.5" WC

(.87 kPa)

Propane

(Lo) 6.3" WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 4

Advertising