Troubleshooting – LG LRTN22310 User Manual

Page 10

Advertising
background image

6. TROUBLESHOOTING

- 10 -

6-1 COMPRESSOR AND ELECTRIC COMPONENTS

Readings OK

Open or short

1

2

3

4

5

2

5

5

3

5

4

5

5

1

4

3

YES

YES

Readings OK

Readings OK

Open or short

Open or short

YES

YES

NO

NO

Power Source.

No Voltage.

(Reated Voltage
±10%)?

Replace OLP.

Reconnect.

Replace
PTC-Starter.

Replace OLP.

Check connection
condition.

OLP disconnected?

Advise customer that
power supply needs to be
checked by an electrician.

Replace
Compressor.

Supply
voltage
rating with
±10%.

Applied voltage isn't
in range of Rating
Voltage ±10%.

Remove PTC-Starter
from Compressor and
measure voltage
between Terminal C of
Compressor and
Terminals 5 or 6 of PTC.

Check resistance
between M-C, S-C and
M-S in Motor
Compressor.

Check resistance of
two terminals in
PTC-Starter.

Check resistance of
two terminals in OLP.

Check the power supply
under load.
(Compressor attempting
to re-start after being off
for 5 minutes).

Check
resistance of
Motor
Compressor.

Check
resistance of
PTC-Starter.

Check OLP.

Check
starting state.

Did
compressor
start?

Compressor
is OK

Replace the
compressor