LG LRTN22310 User Manual

Page 15

Advertising
background image

- 15 -

NO.

ITEMS

UNIT

STANDARDS

PURPOSES

REMARKS

General Control of Refrigerating Cycle

Pipe and
piping system
opening time

Welding

N

2

sealed

parts

Refrige-
ration
Cycle

Refrigerant
weighing

Drier
replacement

Leak check

1

2

3

4

5

6

7

Min.

Nitrogen
pressure

Confirm
N

2

leak

Min.

Torr

EA

EA

EA

EA

Pipe: within 1 hour.
Comp: within 10 minutes.
Drier: within 20 minutes.

Weld under Nitrogen
atmosphere.
(N

2

pressure:

0.1~0.2 kg/cm

2

)

Confirm the sound of
pressure relief when
removing the rubber cap.
Sound: usable
No sound: not usable

More than 40 minutes

Below 0.03 (ref)

High and low pressure sides
are evacuated at the same
time for models above 200

l.

Use R-134a manifold
exclusively.

Use R-134a manifold
exclusively.

R-134a manifold exclusively.

R-134a manifold exclusively.

Use R-134a exclusively.
Weighing allowance:

±5g

Note: Winter: -5g

Summer: +5g

- Use R-134a exclusively for

R-134a refrigerator.

- Replace drier whenever repairing

refrigerator cycle piping.

- Do not use soapy water for

check. It may be sucked
into the pipe by a vacuum.

To protect
moisture
penetration.

To protect oxide
scale formation.

To protect
moisture
penetration.

To remove moisture.

To protect mixing
of mineral and
ester oils.

To protect R-12
refrigerant mixing.

To protect R-12
refrigerant mixing.

To protect R-12
refrigerant mixing.

Do not mix with
R-12 refrigerant.

To remove the
moisture from
pipe inside.

Defect in
refrigerant leak
area.

The opening time should be reduced
to a half of the standards during rain
and rainy seasons (the penetration of
water into the pipe is dangerous).

- Refer to repair note in each part.
- R-134a refrigerant is more

susceptible to leaks than R-12 and
requires more care during welding.

- Do not apply force to pipes before and

after welding to protect pipe from cracking.

- In case of evaporator parts, if it doesn't

make sound when removing rubber
cap, blow dry air or N

2

gas for more

than 1 min. and than use the parts.

Note: Only applicable to the model

equipped with reverse flow
protect plate.

Vacuum efficiency can be improved
by operating compressor during
evacuation.

The rubber pipes for R-12 refrigerant
will be melted when they are used for
R-134a refrigerant (causes of leak.)

- Do not weigh the refrigerant at too

hot or too cold an area.
(77°F [25°C] is adequate.)

- Make Copper charging canister

(Device filling refrigerant)
Socket: 2SV Plug: 2PV R-134a
Note: Do not burn O-ring (bushing)

during welding.

- Check for an oil leak at the refrigerant

leak area. Use an electronic leak
detector if an oil leak is not found.

- The electronic leak detector is very

sensitive to halogen gas in the air. It
also can detect R-141b in urethane.
Practice many times before using this
type of detector to avoid false readings.

Evacuation
time

Vacuum
degree

Vacuum

Vacuum
piping

Pipe
coupler

Outlet
(Socket)

Plug