12. CONDENSER

1. Remove the cabinet. (Refer to section 2)
2. Remove the brace and the shroud cover.

(Refer to section 4)

3. Remove the 5 screws which fasten the condenser.
4. After discharging the refrigerant completely,

unbraze the interconnecting tube at the condenser
connections.

5. Remove the condenser.
6. Re-install the components by referring to notes.

(See Fig. 38)

13. EVAPORATOR

1. Remove the cabinet. (Refer to section 2)
2. Discharge the refrigerant completely.
3. Remove the 2 screws which fasten the evaporator

at the left side and the right side.

4. Move the evaporator sideward carefully and then

unbraze the interconnecting tube at the evaporator
connectors.

5. Remove the evaporator.
6. Re-install the components by referring to notes.

(See Fig. 39)

14. CAPILLARY TUBE

1. Remove the cabinet. (Refer to section 2)
2. After discharging the refrigerant completely,

unbraze the interconnecting tube at the capillary
tube.

3. Remove the capillary tube.
4. Re-install the components by referring to notes.

FIG. 38

FIG. 39

Refrigerating Cycle

Discharge the refrigerant system using Freon

TM

Recovery System.
If there is no valve to attach the recovery system,
install one (such as a WATCO A-1) before vent-
ing the Freon

TM

. Leave the valve in place after

servicing the system.

CAUTION