NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Positive Flue

Connector Ring

(sold separately)

Rigid Pipe, Offset Box or

Flex Pipe Adaptor

Top of Insert

In Back

Figure 7 - Connector Ring Kit

A positive flue connection is providing a seal between the vent pipe or

liner and the existing fireplace chimney for the purpose of preventing

room air passage to the chimney cavity of the fireplace. There are differ-

ent approved methods to achieve this. See Direct Connect Positive Flue

Connection on this page.

When creating a positive flue connection, a positive flue connector ring

kit is required (sold separately - see Figure 7). The connector ring kits

(listed below) provide a means to directly attach rigid pipe or an flex
pipe adaptor to the flue outlet.

71162 - 8" Positive Flue Connector Ring Kit
71163 - 8" to 6" Reducer w/ Positive Flue Connector

Install connector ring kits per instructions provided in kits

Direct Connect Positive Flue Connection

Required in Canada

See the following instructions for approved methods of achieving a

positive flue connection - See Figure 8.

A qualified installer should evaluate the existing fireplace to determine

the best method for achieving a positive flue connection between the

vent pipe or liner and the existing fireplace chimney. The most common

method for achieving a positive flue connection in masonry fireplaces

is to secure a seal-off plate (i.e. 22-gage sheet steel) in the fireplace

throat using masonry screws. Other acceptable methods include packing

noncombustible material (i.e. high temp fiberglass or ceramic insulation)

around the vent pipe or using a flue adapter. Whatever “seal off” method

is used, it must effectively seal the area to prevent room air passage to

the chimney cavity of the fireplace.

Offset Boxes

Offsets can be handled using an offset box (it aligns flue outlet of insert

with the fireplace flue (see Figure 9). Care should be used to ensure

that this adjustable offset box is oriented so it does not angle down when

positioned on the insert flue outlet (level or slightly up at the outbound

end is recommended).

Figure 8 - Positive Flue Connection

u

A non-combustible seal is required at the damper area (to prevent

dilution air from entering the chimney). See Direct Connect Positive

Flue Connection on this page. A seal-off plate method is shown here.

u

Side View

of Insert

Fireplace

Chimney

Must extend starter

section past the damper

area as a minimum

Figure 9 - Offset Box Dimensions

C/L

C/L

}

3-3/4”

1-1/2”

5-1/8”

1-1/2”

2-1/8”

H6834 - 17”

H6835 - 22”

SIDE VIEW

TOP VIEW

6” Dia.

8” Dia.

14-1/16”

w

v

v

w

v

Top 6” collar attaches to rigid pipe or flex liner.

w

Bottom 8” collar attaches to connector ring on insert flue outlet.

6”

A full chimney liner

is recommended

Cat. No. H6834, 1/4” to 6-1/4” adjustable

Cat. No. H6835, 6” to 13” adjustable

POSITIVE FLUE CONNECTION