NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

CLEARANCE TO COMBUSTIBLES

See “Required Clearances” on Page 7.

INSERT PRE-INSTALLATION PREPARATION

Install the two 3” (76 mm) long bolts (with the head up) through the nuts

attached to the insert on the lower rear corner of each side. This will allow

you to level the insert when placed into the fireplace.
Measure from the front of the top surround mount to the center of the flue.

Determine if there is an alignment problem in connecting a liner from the

chimney to the insert’s flue. If there is an alignment problem, connection

can be made using a short piece of stainless flex or a stainless steel offset

box (available from your dealer). Before installing the liner, make any

attachment brackets or drill any holes in the liner, offset box, or insert.

Once installed, it may be difficult or impossible to drill additional holes.

Remove the existing chimney cap and install a stainless steel liner into

the chimney (if a special section has been used or drilled to attach to the

insert, it must be the bottom piece). The next piece should be a dripless

slip joint; followed by the rest of the chimney liner. Fasten the chimney

at the top when it is positioned so that the slip joint will allow the lowest

piece to slide up enough to clear the insert during installation. Insulate

the top four to six feet between the liner and the chimney to prevent heat

loss. Install the cap and flash if necessary to prevent water or creosote

from entering the chimney’s venting system.
From inside the fireplace firebox, attach any adapters or flue offsets and

slide the liner up as far as necessary for the bottom piece to clear the

insert during installation.
In Canada, This fireplace insert must be installed with a continuous

chimney liner of 6” or 8” diameter extending from the fireplace insert

to the top of the chimney. The chimney liner must conform to the

Class 3 requirements of CAN/ULC-S635, Standard for Lining Systems

for Existing Masonry or Factory-Built Chimneys and Vents, or CAN/

ULCS640, Standard for Lining Systems for New Masonry Chimneys.

1. Check that all chimney pipe joints are securely fastened.

2. Be sure all roof flashings are watertight (if applicable).

FOR YOUR OWN PROTECTION AND INSURANCE PURPOSES,

HAVE YOUR CHIMNEY AND CONNECTOR PIPE INSTALLATION

INSPECTED BY YOUR LOCAL BUILDING CODE AUTHORITY OR

FIRE MARSHAL BEFORE STARTING A FIRE IN YOUR STOVE OR

INSERT. NOTIFY YOUR INSURANCE COMPANY.

CHIMNEY LINER INSTALLATION

INSTALLING THE INSERT

POST INSTALLATION CHECKS

Place the insert into the fireplace, making sure to center it side to side.

Slide the insert in until the surround mounts are approximately 1/2” (13

mm) from the face of the fireplace where the surround panels cover.
Lower the chimney and make attachment to the insert. Level the fireplace

insert by using a 3/4” socket and a long extension and adjusting the bolts

on either side of the insert.

NOTE: LENNOX HEARTH PRODUCTS RECOMMENDS PROFES-

SIONAL INSTALLATION BY A LICENSED AND BONDED INSTALLER.

SEE YOUR DEALER FOR RECOMMENDATIONS. IMPROPER

INSTALLATION OR MIS-USE WILL VOID YOUR WARRANTY AND

CREATE A SERIOUS SAFETY HAZARD.

Remove any doors or screen materials from the fireplace opening. Re-

move the damper mechanism completely. Also remove grates or ember

catches inside the fireplace hearth. If your fireplace is equipped with a

smoke shelf or baffle and if it interferes with the installation it may be

removed. Side and rear refractory may also be removed, if necessary,

to facilitate installation. No modifications shall be done unless allowed

on the previous list. Retain all removed parts, they must be reinstalled

before the fireplace can be used in it’s original condition.

FIREPLACE PRE-INSTALLATION PREPARATION

FIREPLACE WARNING TAG

The factory built firebox must accept the insert without modification
other than removing bolted or screwed together pieces such as baffles
/ smoke shelf / deflectors, ash lips, glass door, screen or door tracks,
log grates, refractory or masonry lining and damper assemblies. Any
fireplace component, which is removed, must be retained so they can
be reinstalled to restore the fireplace to its original operating condi-
tion. The removal of any part must not alter the integrity of the outer
shell of the pre-engineered fireplace cabinet in any way. Any parts
removed must be replaceable. If any components are removed from
(or altered) from the existing fireplace, a metal Warning tag (shown
below) must be affixed inside the fireplace firebox, so that it shall be
visible upon removal of the fireplace insert. Note: Secure the tag using
screws or nails to the fireplace.

WARNING

THIS FIREPLACE HAS BEEN ALTERED TO

ACCOMMODATE A FIREPLACE INSERT AND

SHOULD BE INSPECTED BY A qUALIFIED

PERSON PRIOR TO RE-USE AS A

CONVENTIONAL FIREPLACE.

Install the side surround panels with the screws supplied. Push the insert

in until there is approximately a 1/4” (6 mm) gap between the back of the

surround panels and the face of the fireplace. Before installing the top

surround panel, make sure all connections are tight and that no part of

the insert or chimney is touching the firebox or chimney in the fireplace.

There must be a minimum of 1” (25mm) clearance between the fireplace

insert and the zero clearance fireplace. Install the top surround panel.
If additional support is necessary, factory punched holes in the front

corners of the bottom air chamber will accept leveling legs. Carefully

measure the distance from the hearth protection to the bottom of the

fireplace insert. Use 3/8” diameter bolts that are 1/2” (13 mm) longer that

the distance just measured. Thread a nut onto the bolt approximately 1”

(25mm). Lift the fireplace insert slightly and insert a bolt into each hole

and then thread the nut up the bolt until the front is securely supported.

Install another nut onto the bolt through the air space in the fireplace insert

and tighten securely. If desired an insert front support, Cat. No. H5296,

is available to fill the space between the insert and the hearth protection.

Install the brick and baffle as per Page 6.