E-2

TROUBLESHOOTING

E-2

MAXsa™ 10 CONTROLLER

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

USING THE STATUS LED TO TROUBLESHOOT

SYSTEM PROBLEMS

The MAXsa 10 is equipped with a Status Light. If a problem occurs it is

important to note the condition of the status lights. Therefore, prior to

cycling power to the system, check the power source status light

for error sequences as noted below.

Included in this section is information about the power source and

Wire Drive Module Status LED’s, and some basic troubleshooting

charts for both machine and weld performance.

The STATUS LIGHTS are dual-color LED’s that indicate system

errors. Normal operation for each is steady green. Error conditions

are indicated in the following Table E.1.

Light

Condition

Steady Green

Blinking Green

Fast Blinking Green

Alternating Green and Red

Steady Red

Blinking Red

Meaning

System OK. Power source is operational, and is communicating normally with all healthy

peripheral equipment connected to its ArcLink network.

Occurs during power up or a system reset, and indicates the POWER

WAVE® i400 is mapping (identifying) each component in the system. Normal

for first 1-10 seconds after power is turned on, or if the system configuration is

changed during operation.

Under normal conditions indicates Auto-mapping has failed.

Also used by the Diagnostics Utility (included on the POWER WAVE® Utilities

and Service Navigator CD’s or available at www.powerwavesoftware.com) to

identify the selected machine when connecting to a specific IP address.

Non-recoverable system fault. If the Status lights are flashing any combination

of red and green, errors are present. Read the error code(s) before the

machine is turned off.

Error Code interpretation through the Status light is detailed in the Service

Manual. Individual code digits are flashed in red with a long pause between

digits. If more than one code is present, the codes will be separated by a

green light. Only active error conditions will be accessible through the Status

Light.

Error codes can also be retrieved with the Diagnostics Utility (included on the

POWER WAVE® Utilities and Service Navigator CD’s or available at

www.powerwavesoftware.com). This is the preferred method, since it can

access historical information contained in the error log.

To clear the active error(s), turn power source off, and back on to reset.

Not applicable.

Not applicable.

TABLE E.1