Troubleshooting, Caution – Lincoln Electric IM10023 User Manual

Page 40

Advertising
background image

E-5

TROUBLESHOOTING

E-5

MAXsa™ 10 CONTROLLER

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Observe all Safety Guidelines detailed throughout this manual

Err 44

Main CPU problem.

Err 53

Voltage sense loss.

Err 54

Short term secondary over-

current.

Err 81

Motor overload, long term.

Err 82

Motor overload, short term.

1. Verify the earth ground connec-

tion to the power source is wired

correctly.

2. See the power source Instruction

Manual.

1. Verify correct sense lead connection.

1. The wire drive motor has over-

heated. Check that the electrode

slides easily through the gun and

cable.

2. Remove tight bends from the gun

and cable.

3. Check that the spindle brake is

not too tight.

4. Verify a high quality electrode is

being used.

5. Wait for the error to reset and the

motor to cool (approximately 1

minute).

6. Long term average motor current

l i m i t

h a s

b e e n

e x c e e d e d .

Typically indicates mechanical

overload of system. If problem

continues consider higher torque

gear ratio (lower speed range).

1. The wire drive motor current draw

h a s e x c e e d e d l i m i t s , u s u a l l y

because the motor is in a locked

rotor state. Check that motor can

turn freely when idle arm is open.

2. Verify that the gears are free of

debris and dirt.

If all recommended possible areas

of misadjustment have been

checked and the problem persists,

Contact your local Lincoln

Authorized Field Service Facility.

ARCLINK SYSTEM ERROR CODES

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Advertising