A-3

Other Specifications

Switch Fabric

●

Full digital, nonblocking

Electrical
Specifications

●

35 Watts (120 BTUs/hr.) per ACS processor module during normal power

consumption

●

45 Watts (154 BTUs/hr.) per ACS processor module during maximum power

consumption

●

10 Watts (35 BTUs/hr.) per 400 module, normal and maximum power consumption

●

25 Watts (90 BTUs/hr.) per 206 module during normal power consumption

●

35 Watts (120 BTUs/hr.) per 206 module during maximum power consumption

●

30 Watts (105 BTUs/hr.) per 308EC module during normal power consumption

●

40 Watts (140 BTUs/hr.) per 308EC module during maximum power consumption

●

U.S., Canada, and other 110V countries:

— ACS processor module and one 206 module (2-Slot carrier) = 2.3 Amps max.

current, full system capacity

— ACS processor module and four 206 modules (5-Slot carrier) = 4 Amps max.

current, full system capacity

●

Countries using 220V:

— ACS processor module and one 206 module (2-Slot carrier) = 1.2 Amps max.

current, full system capacity

— ACS processor module and four 206 modules (5-Slot carrier) = 2 Amps max.

current, full system capacity

●

45 days to 6 months memory backup with 2 AAA-size standard alkaline batteries

(IEC LR03)

Processor Module
Specifications

●

68306 16 Mhz processor

●

512Kbyte RAM

●

512Kbyte FLASH ROM

●

Polarity reversal detection on the CO line port

●

Custom VLSI DSP ASIC—16bit, 52 Mhz

— VLSI = Very Large Scale Integration

— DSP = Digital Signal Processor

— ASIC = Application Specific Integrated Circuit

Extension Jack
Specifications

(206 module)

●

Ringing voltage: +5VDC, -140 VDC peak to peak; trapezoidal wave shaping

●

35- to 38-Volt talk battery

●

Ringing frequency: 20 Hz

Extension Jack
Specifications

(ACS Processor and
308EC module)

●

Ringing voltage: +55VRMS Balanced ringing within a trapezoidal wave shaping

●

38- to 42-Volt talk battery

●

Ringing frequency: 20 HZ

●

Polarity reversal detection on the CO line port

●

56K modem bypass to the Power Fail Transfer (PFT) relays

PAGE Jack
Specifications

●

Draws current on inner wire pair

●

Provides paging contact closure on outer wire pair

●

600 Ohm impedance

Music-on-Hold Jack
Specifications

●

Accepts 2 Volts at 50 Kohms maximum input

●

0 - 18 dB attenuation