Contact closure group (#612), Description, Related features – Polycom TransTalk 9000-Series User Manual
Page 202: Valid entries, Programming, Contact closure group (#612) s
 
Feature Reference
5-92
Contact Closure Group (#612)
Description
The PARTNER ACS processor module has a jack to connect a Contact Closure 
Adjunct that has two Contact Closures. This System Programming procedure 
allows you to specify which user extensions can activate each Contact Closure. 
The Contact Closures can control devices such as electronic door locks. 
Related Features
■
Use Contact Closure Operation Type (#613), to specify how long each 
Contact Closure remains active when activated.
■
If a Contact Closure is used to control a door lock and a doorphone is 
installed at that door, you may want to assign the extensions in the Contact 
Closure Group to also be the Doorphone Alert Extensions (#606) for that 
doorphone.
■
When a user’s extension is included in the appropriate Contact Closure 
Group, the user can then use Contact Closure to activate the contact 
closure device.
Valid Entries
1 = Assigned to the Contact Closure Group
2 = Not Assigned to the Contact Closure Group 
✔
Programming
(See Figure 2-3 on page 2-22 for the location of special programming buttons such 
as 
s
and
e
on system phones.)
To assign extensions to a Contact Closure Group:
1. Press
f 0 0 s s # 6 1 2
at extension
10 or 11.
2. At the
Contact Number:
prompt, enter the number for the Contact
Closure (1 or 2). For example, to assign extensions to Contact Closure 1, 
press 
1
.
3. At the
Extension:
prompt, enter the two-digit extension number that you
want to assign to this Contact Closure Group. For example, to assign 
extension 14 to this group, press 
1 4
.
4. To assign or unassign the extension, press
D
until the appropriate
value displays.