Hold disconnect time (#203), Description, Considerations – Polycom TransTalk 9000-Series User Manual

Page 267: Valid entries

Advertising
background image

Hold Disconnect Time (#203)

5-157

Hold Disconnect Time (#203)

Description

This System Programming procedure lets you change the hold disconnect time
for an outside line. When a caller on hold hangs up, the local telephone company
may send a special signal to the system to free the line. Different telephone
companies use different length signals. The length of the signal is called the hold
disconnect time. If you put a call on hold and the caller hangs up, but the call does
not disconnect within a minute after the caller hangs up, the hold disconnect time
is probably set too high, or set at No Detection.

Considerations

■

If the telephone company does not send a signal, keep the hold disconnect
time set to 450 msec, the default setting. The user must disconnect a held
call manually by retrieving the call then hanging it up.

■

Shorten the hold disconnect time only if abandoned calls on hold do not
disconnect.

■

Lengthen the hold disconnect time only if calls are being disconnected
prematurely.

Valid Entries

00 = No Detection
01 = 50 msec
02 = 100 msec
03 = 150 msec
04 = 200 msec
05 = 250 msec
06 = 300 msec
07 = 350 msec
08 = 400 msec
09 = 450 msec

✔

10 = 500 msec
11 = 550 msec
12 = 600 msec