Rotary Dialing Timeout (#108)

Description

This System Programming procedure changes the length of the Rotary Dialing
Timeout. You may need to change the length of the timeout if you have any rotary
lines and you are having trouble calling out on standard touch-tone phones. For
example, if users dial slowly and calls are not completed or are connected to
wrong numbers, lengthen the timeout.

Related Features

Use this procedure only if the Dial Mode (#201) for at least one outside line in the
system is set to rotary.

Considerations

Do not change this setting unless the system is experiencing problems.

Valid Entries

1 = 4 seconds
2 = 8 seconds

3 = 12 seconds

Programming

(See Figure 2-3 on page 2-22 for the location of special programming buttons such
as

s

and

e

on system phones.)

To change the length of the Rotary Dialing Timeout:

1. Press

f 0 0 s s # 1 0 8

at extension

10 or 11.

2. Press

D

until the appropriate value displays.

3. Select another procedure or exit programming mode.