Connection with the system controller, Connection to the standby on/off terminal, Setting the termination – Panasonic WV-CM1780 User Manual

Page 8: Ra rb ta tb, Program

Advertising
background image

8

Connection between two or more color monitors and a device compat-

ible with Panasonic Security Data mode

In case of connecting multiple devices compatible with the Panasonic Security Data mode, connect the unit in a daisy-chain
configuration as shown below. The allowable connecting devices are up to 16 in a system. The maximum allowable cable
length of the system is approximately 500 m (1 650 ft).

Connection to the Standby On/Off Terminal

Connecting an external device to the STANDBY ON/OFF Terminal on the rear of the monitor enables control of the monitor dis-
play by input from that device, both in normal and standby display mode.
Shown below is an example of how to use this function.

Connection with the System Controller

If the optional 6-conductor cable assembly is used, simply plug one end of the cable into the DATA port of the Monitor and the
other end into the DATA port on the System Controller.
If you use cables assembled from locally procured materials, it is important that only high quality, data grade cable, suitable
for RS-485 communication (shielded 4-wire twisted pair cable), BELDEN 9406 or equivalent, is used.
Lower grade cable will result in unstable operation of the system.

PROGRAM

System Controller

WV-CU

360

ON OFF

TERMINATION

DATA

ON OFF

TERMINATION

DATA

To the
System Controller

G
N
D

G
N
D

TA TB RA RB

RA

RB

TA

TB

AUDIO

VIDEO

OUT

IN

OUT

A

IN

B

IN

A

IN

B

IN

OUT

OUT

AC IN

S-VIDEO

G

STANDBY

ON
STANDBY

OFF

ON OFF

TERMINATION

FOCUS

DATA

DATA

AUDIO

VIDEO

OUT

IN

OUT

A

IN

B

IN

A

IN

B

IN

OUT

OUT

AC IN

S-VIDEO

G

STANDBY

ON
STANDBY

OFF

ON OFF

TERMINATION

FOCUS

DATA

PROGRAM

System Controller WV-CU

360

Termination: OFF

Termination: OFF

Termination: ON

Termination: ON

Modular
cable
(Supplied:
WV-CU360)

To the Data port
(optional)

System Controller compatible
with PS•Data mode

Device compatible
with PS•Data mode

Setting the Termination

Set the Termination Selector located on the rear of the
monitor according to your requirements.

ON:

Data is terminated.

OFF:

Data is sent to other equipment.

G

STANDBY

ON

STANDBY

OFF

V

L

0.2 V

V

L

0.2 V

Hi-Z

V

H

5 V

Alarm Output

Alarm Reset Output

• STANDBY ON input

Pulse +5 V DC

• STANDBY OFF input

Non-voltage contact or open collector output

Note:

To set up this function, refer to STANDBY ON in

the Display Setting menu.

Advertising