Appendix, Communication protocol, Data format – Panasonic WV-CM1780 User Manual

Page 15: Command table

Advertising
background image

15

APPENDIX

This appendix details the elements for communication between the Monitor and the System Controller. For the communication
parameter settings, refer to the SETUP PROCEDURES on page 9.

Communication Protocol

Data Format

The controller sends messages to operate the monitor in the format shown below.

A transmission message consists of [STX], [Unit Address], [;], [Command], [:], [Parameter], and [ETX]. [Unit Address] is
expressed as [ADuuu] where uuu is in the range of 001 through 099 in decimal form to identify the unit number of the Monitor.

Command Table

The transmission command consists of three letters followed by the unit address.

Code

[STX] [ADuuu] <Unit Address> [;] <Command> [:] <Parameter> [EXT]

ASCII

(02H) ( ) ( ) ( ) ( ) ( ) (03H)

Item

Command (ASCII)

Parameter (ASCII)

Volume Control

VRA : n

n=+

Value Increment

n=–

Value Decrement

Brightness Control

VRB : n

n=+

Value Increment

n=–

Value Decrement

Contrast Control

VRC : n

n=+

Value Increment

n=–

Value Decrement

Sharpness Control

VRS : n

n=+

Value Increment

n=–

Value Decrement

Color Control

VRO : n

n=+

Value Increment

n=–

Value Decrement

Tint Control

VRT : n

n=+

Value Increment

n=–

Value Decrement

AFC Control

VRF : n

n=0

SHORT

n=1

LONG

3.58 MHz Trap Setting

VRP : n

n=0

OFF

n=1

ON

STANDBY ON Setting

MSB : n

n=0

IGNORE

n=1

MODE 1

n=2

MODE 2

STANDBY Button Selection

OSB : n

n=0

Normal Display

n=1

Standby Mode 1

n=2

Standby Mode 2

Input Channel Display

DCH : n

n=0

OFF

n=1

ON

Language Setting

DLA : n

n=0

ENGLISH

n=1

FRANÇAIS

n=2

ESPAÑOL