Infrared ccommunication port diagnosis – Panasonic CF-72 User Manual

Page 25

Advertising
background image

4 - 13

4.4.10. INFRARED CCOMMUNICATION PORT DIAGNOSIS

Make sure that connecting cables, connectors and AC adapter are not loose or disconnected prior to testing.

No.

Symptom

Troubleshooting

procedures

Source of

problem

Component

No.

Result

1

Data cannot be sent or
received.

1-1

Is the Infrared Communica-
tion Port enabled in Setup?

YES

Go to No. 1-2

NO

Improper setting

2

Transmitted data becomes
corrupted.

2-1

Is the transmission distance
within 20-50 cm?

YES

Go to No. 2-2

NO

Use within
specified distance

2-2

Is the transmisson path
clear of obstacles and
interference?
Is the unit operated away
from TV sets, video, wireles
headphones, incandescent
lamps or other electronic
equipment?
Is the unit operated away
from direct sunlight?

YES

Main PCB

IC5

IC21

NO

Change operating
environment

1-2

Is the same transmission
protocol set for both the
sending and receiving units?

YES

Go to No. 1-3

NO

Improper setting

Advertising