TEST AND MEASUREMENT
Issue 1
Section 6
MCUK991001C8
Revision 0
– 40 –
Service Manual
5.
Select VIEW TRIM PL MCH, and make a note of this value.
Figure 6.16: Power level view 2
6.
Perform the following calculation and make a note of the result:
New Trim value = Old Trim Value + (Required Power - Measured Power) x Change per dB
(step 5)
(table)
(step2)
(table)
Make a note of the result.
7.
At the Channel box press F6 to program the TRIM for the mid-channel.
Figure 6.17: Power level selection 1