Adjustment mode, 5 adjustment mode – Panasonic EB-GD30 User Manual

Page 43

Advertising
background image

TEST AND MEASUREMENT

MCUK991001C8

Section 6

Issue 1

Service Manual

– 37 –

Revision 0

6.5 Adjustment Mode

NOTE:

See Section 6.2.1 for a list of the equipment and setup procedures required to perform the following adjustment
and calibration procedures.

The following procedures MUST be performed after replacement or repair of one or both of the PCBs in the handheld unit.
Failure to do so may result in incorrect operation of the telephone.

The following adjustments MUST be made on BOARD PAIRS.

There are three distinct calibration procedures to adjust RF performance. These procedures are:

1.

Ramping gain (Section 6.5.1)

2.

RSSI (Section 6.5.2)

3.

I and Q values (Section 6.5.3)

The adjustment data selected during calibration is stored in the telephone EEPROM.

Figure 6.13: Test software screen

SET ER.DISP

<ENABLE>
<DISABLE>

Unit error codes will be displayed on the UUT
display
Unit error codes will not be displayed on the
UUT display

SOFT SIM

<ENABLE> <DISABLE>

With ENABLE set and TEST MODE <TERM>
the UUT is removed from test mode and can be
placed into call mode

TEST MODE

<TERM>

With SOFT SIM <ENABLED> the UUT will be
removed from test mode and can be placed into
a call

SIM STATUS

<SHOW>

Checks and displays the SIM status

CHECK SUM

<SHOW>

Displays the software checksum

CHANNEL BOX COMMAND

INDICATION

FUNCTION

Advertising
This manual is related to the following products: