Offset, Sn threshold – Printronix ThermaLine T5000r User Manual

Page 62

Advertising
background image

Chapter 2

Configuring The Validator

62

To write a new Gain value to the validator’s flash memory, save a
configuration. See “Saving A Configuration” in the

Quick Setup

Guide.

NOTE: This value will not be saved in the configuration. It will only

be written to the validator’s flash memory.

Offset

This menu item sets the scanner offset setting. This allows you to
adjust the vertical position of the scan profile to guarantee that the
validator hardware is reading the bar codes within the optimal
range. You can adjust this to place the bar code profile in the center
of the profile scale above 10% and below 90%.

NOTE: This menu does not have a default setting because the

value is hardware dependent. The initial value is read from
the validator’s flash memory.

After the initial value has been determined, you can set the Offset
parameter to a value from 1 to 255.

To write a new Offset value to the validator’s flash memory, save a
configuration. See “Saving A Configuration” in the

Quick Setup

Guide.

NOTE: This value will not be saved in the configuration. It will only

be written to the validator’s flash memory.

SN Threshold

This menu item sets the SN (signal to noise) threshold used by the
validator to discriminate between high peak noise and actual bar
code transitions. Any reflectance transitions that are below the
threshold are ignored and considered noise.

You can set the SN Threshold to a value from 5 to 199.
The default is 70.

1.

Press

to take the printer offline and place the printer in

Menu mode.

2.

If necessary, press

and

at the same time to unlock the

key.

3.

If necessary, press

until VALIDATOR displays.

4.

Press

until SN Threshold displays.

..

.

..

.

Advertising