Chapter 2

Configuring The Validator

60

2.

If necessary, press

↓

and

↵

at the same time to unlock the

↵

key.

3.

If necessary, press

until VALIDATOR displays.

4.

Press

↑

until EC Min displays.

5.

Press + or – to scroll through the percentage values: 0% to
100%. The default is 15%.

6.

Press

↵

to select the desired value.

7.

Press

↓

and

↵

at the same time to lock the

↵

key, then press

PAUSE to take the printer offline.

8.

Press PAUSE again to put the printer online.

Rmin

NOTE: This parameter factors into the Overall Grade (page 57).

This menu item sets the minimum reflectance value used by the
validator for pass/fail threshold used during the analysis of bar
codes. A bar code will fail if all the bar reflectance values are above
the percentage of space reflectance set by this threshold. For
example, an Rmin setting of 50% requires that at least one bar
reflectance value fall under the mid point of the reflectance value
read for the highest space reflectance.

You can set the Rmin parameter to a percentage value from 0% to
100%. The default is 50%.

1.

Press

to take the printer offline and place the printer in

Menu mode.

2.

If necessary, press

↓

and

↵

at the same time to unlock the

↵

key.

3.

If necessary, press

until VALIDATOR displays.

4.

Press

↑

until Rmin displays.

5.

Press + or – to scroll through the percentage values: 0% to
100%. The default is 50%.

6.

Press

↵

to select the desired value.

7.

Press

↓

and

↵

at the same time to lock the

↵

key, then press

PAUSE to take the printer offline.

8.

Press PAUSE again to put the printer online.

..

.

..

.

..

.