Connections with ps • data equipment, Connections with ps, Data equipment – Panasonic WJ-HD100 User Manual

Page 11: On off power, Data multiplex unit video multiplexer

Advertising
background image

11

Connections with PS

Data Equipment

PS

Data equipment must be set up for communication as follows:

• Protocol selection: PS

DATA

• Unit Address: Set an address unique in the chain.
• Baud rate, data bit length, parity check, stop bit: Choose the same settings as used for the other equipment in the chain.

Recommended video multiplexers are Panasonic’s WJ-FS series or similar models having specifications as follows.

• Switching recognition signal is located within 8H prior to the end of vertical blanking.
• A camera switching rate of 4/60 seconds or more is available.

SIGNAL GND

ALARM

SERIES

RECORD

TIME

ADJUST

REMOTE

MODE

DATA

RS-232C

VIDEO

OUT

IN

OUT

IN

AUDIO

MONITOR OUT

(PLAY)

CAMERA
SW OUT

G

G

G

JOG-CLICK

JOG-LEFT

JOG-RIGHT

ALARM SEARCH

STEP

REW/FF

STOP/SETUP

PLAY

REC

OUT

PLAY OUT

REC OUT

AUTO OFF OUT

DISK END OUT

IN

OUT

IN

RECALL

OUT

RECOVER OUT

RESET IN

IN

POWER

ON

OFF

ON

OFF

POWER

POWER

ON

OFF

ALARM

Data Multiplex Unit WJ-MP204

ALARM

SUSPEND

System Controller

POWER

ON

OFF

ON

Camera

DATA Port

DATA Port

Multi Screen
Out

Data Multiplex Unit

Video Multiplexer

Camera In

Camera Out

Video Monitor

Set the termination to
ON for the units at both
ends of the chain, and to
OFF for units in the
middle.

System Controller with PS•Data
Capability

DATA Port

Digital Disk Recorder WJ-HD100

Monitor Out

Video In

Video In

Rec
Out

Play
In

Video In

DATA Port

MODE

CAM SW
In

Camera SW
Out

(EXT REC)

Note:
Set the field rate to
7.5 fps or slower when
connecting the Camera
SW Out signal with the
video multiplexer.

If the cable is locally procured, make sure it is data
grade cable suitable for RS-485 communication. A 2-
wire twisted pair shielded cable, BELDEN 9406 or
equivalent should be used. Pin assignments and data
flow are shown below.

1

6

1

6

No.

No.

Name

Data Flow

1

1

GND

2

2

RX(B) WJ-HD100

WV-CU360

3

3

RX(A) WJ-HD100

WV-CU360

4

4

TX(B) WJ-HD100

WV-CU360

5

5

TX(A) WJ-HD100

WV-CU360

6

6

GND

Controller
end

Advertising