ALARM RECOVER OUT

14

MODE

ON

Termination

Unit Address/Initializing

Alarm Out Polarity

1 2 3 4

5 6

Mode Switch Setting

The 6-bit DIP switch on the rear panel is used as follows.

#1 through #4:

For setting the unit address or initializ-

ing the setup data

#5:

Termination for communication lines

#6:

For setting the polarity of the alarm output signal

Unit Address & Initialize

The unit address can be set either on the setup menu
or by setting this DIP switch.

MODE

ON

1 2 3 4

5 6

MODE

ON

1 2 3 4

5 6

MODE

ON

1 2 3 4

5 6

MODE

ON

1 2 3 4

5 6

MODE

ON

1 2 3 4

5 6

Unit address is specified in
the setup window.

Unit address 1

Unit address 2

Unit address 3

All disk contents and setup
data are initialized.

Note: Do not use switch combinations other than shown above.

Termination

Set DIP switch #5 to ON or OFF position depending on the
type of connection and the unit's position within the daisy
chain.

Daisy Chain Connection:

Set the termination to ON for the

units at both ends of the RS-485 chain (PS

Data), and to

OFF for units in the middle.

Homerun Connection:

For a one-to-one connection, set

the termination to ON.

ON

Termination Switch

MODE

1 2 3 4

5 6

System Component

Termination ON

Termination OFF

Termination
OFF

Termination
OFF

Termination
ON

System

Controlle

r WU-CU

360

360

For PS.D

.LINK

8

9

7

0

4

5

6

2

3

1

System

Controlle

r WU-CU

360

360

For PS

.D.LIN

K

8

9

7

0

4

5

6

2

3

1

System

Controlle

r WU-CU

360

360

For P

S.D.LINK

8

9

7

0

4

5

6

2

3

1

Alarm Output Polarity

The DIP switch #6 specifies the polarity of ALARM OUT and
ALARM RECOVER output signals. Select [active-low] or
[active-high] depending on the type of the connected
device. See the manual included in the connected device
for acceptable signal polarity. The default setting is ON
[active-high].

MODE

ON

Polarity switch

1 2 3 4

5 6

Switch #6 vs Polarity (when active)

ALARM OUT

ON (active-high)

OFF (active-low)

Open-collector low

Open-collector low

+12 V DC

+5 V DC

Advertising