Setting up the Power Supply

WARNING —Risk of electrical shock or electrocution.

A ground fault current interrupter (GFCI) must be in place to protect your electric outlet . Failure to do
so could create an electrical hazard which could result in death or serious injury to pool or spa users,
installers, or others due to electrical shock, and may also cause damage to property.

The power supply MUST be placed a minimum distance of 10 feet away from the pool. Failure
to do so could create an electrical hazard which could result in death or serious injury to pool or spa
users, installers, or others due to electrical shock, and may also cause damage to property.

CAUTION — Never power the cleaner “ON” if it is not fully immersed in water.

This cleaner has an internal timer, which will automatically shut off the cleaner after 2 hours of
operation. However, the Switch will remain in the “ON” position. To re-start the cleaner for another
cycle, switch the Power Supply “OFF”, and then switch it back to the “ON” position and press the
Reset Button. See

Figure 1

.

1. Place the Power Supply in a dry, sheltered area at least 10 feet away from the pool, see Figure 3. Since the

Power Supply is water resistant, not water proof, it should not be left out in the rain or placed in puddles
of water.

2. Plug the Power Supply Cord into a 115V, three prong grounded GFCI outlet. If an outlet is not close enough,

a grounded 115V extension cord may be used to connect to the nearest outlet, see Figure 4.

At Least 10 Feet

(Remember to keep the Power Supply at least 10 feet away from the pool.)

Figure 3.

Figure 4.