SoundStation Premier

Installation Instructions and User's Guide

14

Extended Microphones

Size:

4.125 in 3 in 1in

Weight: 0.25 lb (0.10 Kg)

Cabling: Two-wire RJ9, 8ft

Environmental Requirements

Temperature: 5° - 40° C operating
Humidity:

20% - 85% non-condensing

Recommended Room Conditions

Reverberation time: < 0.4 seconds
Noise level:

< 48 dBA

Registration

UL, FCC, Industry Canada, CE

Audio Bandwidth

200 to 3500 Hz

Loudspeaker Volume

89 dBSPL

Network Interface

NORTEL

®

Meridian

®

, Meridian 1

(option 11 to 81), SL-1, or SL-100 digital PBX

SystemPower Requirements

90-110 VAC, 60 Hz.

Console

Power: 20 VDC, 800 mA

Size:

13.8 in 13 in 2.5 in

(35cm

33cm 6.4cm)

Weight: 2.0 lbs (0.9 Kg)

Interface Module

Power: 20 VDC, 150 mA

Size: 3.125

in 7.75 in 1.875 in

(7.9cm

19.7cm 4.8cm)

Weight: 0.75 lbs (0.34Kg)

Cable length to console:

25 ft (7.6m) to console

Cable length to telephone wall jack:

6 ft (1.8m)

RCA jack:

Line level to tape recorder

or Remote Lapel

Microphone