2.106. Query KEYSTONE

Hexadecimal 02h 51h 4Bh 53h

03h

Character Q K S

Response (Callback)

In the period when the command can be accepted

Hexadecimal 02h *1 *3 *5 03h

Character *2 *4 *6

Acceptability

SECURITY STANDBY NO

SIGNAL AV MUTE REMOTE

Parameters (*1, *2, *3, *4, *5, *6)

32

31

30

Hexadecimal 2Dh

33h 32h 2Dh

33h 31h 2Dh

33h 30h

Character

3 2 - 3 1 - 3 0

30 31 32

Hexadecimal 30h 33h 30h 30h 33h 31h 30h 33h 32h

Character 0 3 0 0 3 1 0 3 2

2.107. Query SHIFT H

Hexadecimal 02h 51h 48h 50h

03h

Character Q H P

Response (Callback)

In the period when the command can be accepted

Hexadecimal 02h *1 *3 *5 03h

Character *2 *4 *6

Acceptability

SECURITY STANDBY NO

SIGNAL AV MUTE REMOTE

Ч

Ч

Parameters (*1, *2, *3, *4, *5, *6)

127

126

125

Hexadecimal 2Dh 31h 32h 37h 2Dh 31h

32h

36h 2Dh 31h 32h 35h

Character

1 2 7 - 1 2 6 - 1 2 5

125 126 127

Hexadecimal 31h

32h 35h 31h

32h

36h

31h

32h

37h

Character 1 2 5 1 2 6 1 2 7

Note:

This command is not acceptable when the input is NETWORK.

2.108. Query SHIFT V

Hexadecimal 02h 51h 56h 50h

03h

Character Q V P

Response (Callback)

In the period when the command can be accepted

Hexadecimal 02h *1 *3 *5 03h

Character *2 *4 *6

Acceptability

SECURITY STANDBY NO

SIGNAL AV MUTE REMOTE

Ч

Ч

Parameters (*1, *2, *3, *4, *5, *6)

64

63

62

Hexadecimal 2Dh

36h 34h 2Dh

36h 33h 2Dh

36h 32h

Character

6 4 - 6 3 - 6 2

62

63

64

Hexadecimal 36h 32h 36h 33h 36h 34h

Character 6 2 6 3 6 4

Note:

This command is acceptable except when the input is NETWORK. Or, this command is acceptable when the

input is NETWORK and ASPECT is H-FIT (for FW300 series only). In other cases, ER401 is returned.