2.5. FREEZE

Hexadecimal 02h 4Fh 46h 5Ah

3Ah

*1 03h

Character O F Z : *2

Parameters (*1, *2)

FREEZE OFF

FREEZE ON

Hexadecimal 30h

31h

Character 0

1

Response (Callback)

In the period when the command can be accepted

Hexadecimal 02h 4Fh 46h 5Ah 3Ah *1 03h

Character O

F

Z :

*2

Acceptability

SECURITY STANDBY NO

SIGNAL AV MUTE REMOTE

Ч

Ч

Ч

Ч

2.6. INPUT

SELECT

Hexadecimal 02h 49h 49h 53h 3Ah

*1 *3 *5 03h

Character I I S : *2 *4 *6

Parameters (*1, *2, *3, *4, *5, *6)

COMPUTER1

COMPUTER2

Hexadecimal 52h 47h 31h 52h 47h 32h

Character R G 1 R G 2

VIDEO

S-VIDEO

Hexadecimal 56h 49h 44h 53h 56h 44h

Character V

I

D

S

V

D

DVI

NETWORK

Hexadecimal 44h 56h 49h 4Eh 57h 50h

Character

V I N W P

Response (Callback)

In the period when the command can be accepted

Hexadecimal 02h 49h 49h 53h 3Ah *1 *3 *5 03h

Character I I S :

*2

*4

*6

Acceptability

SECURITY STANDBY NO

SIGNAL AV MUTE REMOTE

×

Notes:

During STANDBY, this command is available only when IN STANDBY MODE is ON.

REMOTE is given to priority. Calls back ER402 if INPUT SELECT by REMOTE is effective.

2.7. MENU

Hexadecimal 02h 4Fh 4Dh 4Eh 03h

Character O

M

N

Response (Callback)

In the period when the command can be accepted

Hexadecimal 02h 4Fh 4Dh 4Eh 03h

Character O

M

N

Acceptability

SECURITY STANDBY NO

SIGNAL AV MUTE REMOTE

Ч

Ч

2.8. ENTER

Hexadecimal 02h 4Fh 45h 4Eh 03h

Character O

E

N

Response (Callback)

In the period when the command can be accepted

Hexadecimal 02h 4Fh 45h 4Eh 03h

Character O

E

N

Acceptability

SECURITY STANDBY NO

SIGNAL AV MUTE REMOTE

Ч

Ч

Advertising