Philips Lightolier SORA-5 User Manual

Sora-5, Lighting systems, S2 4

Advertising
background image

Job Information

Type:

Job Name:

Cat. No.:

Lamp(s):

Notes:

"JSQPSU3PBE 'BMM3JWFS ."t  t'BY  
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt

Lighting Systems

SORA-5

1BHFPG

-JHIU51FS'PPU /PNJOBM 4FDUJPO

#

Ordering Information

S

2

4

Body

Family

Lamps

Wattage

Style

Length

Finish

2 = 2 Lamps Per

28 = 28 Watt
54 = 54 Watt

with Wings

CW= Suspended

4 = 4 Foot

Nominal

SC = Platinum
WH = White

Complete Ordering Instructions below.

4-Foot Section

Features

1. Housing: Aluminum extruded upto 4-foot nominal lengths.
2. Lamp: T5 linear fluorescent, 28 or 54 watt. (by others).
3. Reflector: Die-formed high reflectance semi-specular aluminum.
4. Lens: Translucent matte white acrylic, 0.20” (0.51cm) thick.

Electrical

Ballast is electronic, low harmonic distortion, high power and ballast factor, uni-
versal voltage with two conductors and a ground. Mark X dimming (no extra control
wire required) is available. EM battery pack not available. Modules can be
continuously wired row mounted, but cannot exceed amperage limits of electrical
supply cords. Cable suspended fixtures have 18/3 SJT cord, stem products have
three 18 gauge wires provided in stem, and both versions must be hard wired.
Factory installed ballast disconnect allows the ballast to be disconnected from and
reconnected to incoming power under load without turning the entire circuit off.

Mounting

Cable mounting utilize 1/16” (0.16cm) diameter SSTL aircraft cable, and are
continuously adjustable via a cable gripper. Stem mountings utilize 1/8 IP stems
(three wires only) with ball swivel mounting at ceiling line. Stems cannot be cut in
field and should be ordered to required length. 4-1/2” (11.43cm) diameter canopies
are used on both styles. 12-foot fixtures may have up to 1/4” (0.64) deflection in
luminaire housings.

Finish

Powder coated Steelcase Platinum or White baked enamel.
Custom colors available, consult factory.

Labels

UL (1598), cUL and I.B.E.W.

CW

Continuos Rows:
1. Determine run length.
2. Order the appropriate number of Modules to complete the run.
3. Order one End Set per run.
4. Order one Intermediate suspension per Module minus one per run.
5. For runs that exceed amperage limits, order the appropriate number of

Intermediate suspension Power (for cable suspended units only).

Ordering Instructions

Individual fixtures:
1. Order number of Modules required.
2. Order one End Set per module.

2.38”

(6.05cm)

13.28”

(33.73cm)

7.96” (20.22cm)

1

2

3

4

21.22” (53.90cm)

Advertising