Monitor lamp indicators, English, Temp indicator – Panasonic TQBJ0350 User Manual

Page 77

Advertising
background image

Monitor Lamp indicators

ENGLISH -

77

Maintenance

J

TEMP indicator

Lamp

indication

Information

Check point

Remedial measure

Lighting in red

Warm-up status

Did you turn on the power when

z

the ambient temperature was

lower than approx. 0 °C (32 °F)?

Wait about 5 minutes in the current

z

status.

Install the unit in a location having

z

an ambient temperature from 0 °C

(32 °F) - 45 °C (113 °F).

High temperature

inside. (WARNING)

Check the ventilation port is

z

blocked.

Is the room air temperature too

z

high?

Is the filter indicator lighted?

z

Remove the object that is blocking

z

the ventilation port.

Move the projector to a temperature

z

of 0 °C (32 °F) - 45 °C (113 °F) and

the humidity of 20 % to 80 % (no

condensation).

Turn off the MAIN POWER switch

z

using the procedure on page 34 and

replace the ACF unit.

Blinking in red

(once)

High temperature

inside.

(Standby condition)

Blinking in red

(twice)

High temperature

inside.

(Power ON condition)

Blinking in red

(3 times)

Cooling fan has

been stopped.

Turn off the MAIN POWER switch

z

using the procedure on page 34 and

consult the dealer.

Note

If no problem is found or the problem remains, do not turn on the projector. Instead contact your dealer.

z

Advertising
This manual is related to the following products: