STEP 7

Install the NEW PRIMARY CABLE (13) using the following steps:

• Route the CABLE (13) back over one pulley in the GUIDE ROD SUPPORT, down through the PULLEY BRACKET (2) and over the

second pulley in the GUIDE ROD SUPPORT.

• Route the CABLE (13) around the FLOATING PULLEY BRACKET as shown in FIGURE 7.

• Route the CABLE (13) through the TOP BOOM as shown in FIGURE 7. The pulleys in TOP BOOM may need to be temporarily removed

to perform this step. (Note: Make sure the CABLE is running in all the pulley grooves.)

FIGURE 7

2

13

• Screw the threaded end of CABLE (13) into the HEAD PLATE ASSEMBLY.

IMPORTANT: Cable must run

in all the pulley grooves.