V.34 – Paradyne 392xPLUS User Manual

Page 62

Advertising
background image

DCP Operation

3-25

3920-A2-GN31-30

November 1996

V.34

When running V.34 modulation, this function displays information about the modem’s receiving
and transmitting data rate, symbol rate, transmitting level, and asymmetric rate.

NOTE

The V.34 status display is available only when the modem is
configured for V.34 modulation.

To access V.34 from the Status branch, make the following selection:

F1

Status:
DTE

V.34

F2

F3

Select V.34.

F1

Status: V.34
TxRate = xxxx Kbps

F2

F3

If the modem is receiving a signal, the signal quality appears on the second LCD line. Press the

key to scroll and view the V.34 modem receive rate, symbol rate, transmit rate, and

asymmetric. If the modem is not receiving a signal, the message No Sync appears.

TxRate

Modem Transmit Rate indicates the rate at which the modem is transmitting
data. Possible values are 2400, 4800, 7200, 9600, 12.0 (12,000), 14.4 (14,400),
16.8 (16,800), 19.2 (19,200), 21.6 (21,600), 24.0 (24,000), 26.4 (26,400),
28.8 (28,800), 31.2 (31,200), or 33.6 (33,600) bps.

RxRate

Modem Receive Rate indicates the rate at which the modem is receiving data.
Possible values are 2400, 4800, 7200, 9600, 12.0 (12,000), 14.4 (14,400),
16.8 (16,800), 19.2 (19,200), 21.6 (21,600), 24.0 (24,000), 26.4 (26,400),
28.8 (28,800), 31.2 (31,200), or 33.6 (33,600) bps.

SymbolRate

Symbol Rate indicates the baud rate used by V.34 modulation. Refer to CCITT
specifications. Possible values are 3429, 3200L, 3200H, 3000L, 3000H,
2800L, 2800H, 2743L, 2743H, 2400L, 2400H.

TxLevel

Transmit Level indicates the power level at which the modem is transmitting
when running V.34 modulation. Possible values are 01– 64 dBm.

AsymRate

Asymmetric Rate indicates the rate symmetry when running V.34 modulation.
Refer to the Asymmetric Rate configuration option in the Dial Line or Leased
Line
section of Chapter 4.

Advertising