35

3. Setup

3-5. Setting the sync signals

The sync signals to be used by the system can be selected.

External sync: For synchronization with an external sync signal (gen-lock). The reference input signal is

looped through and output.
BBST: Black burst signal (vertical phase of 0H)
BBAD: Black burst signal

This can be selected when HD format signals are supplied.
( Vertical phase of 90H when the 59.94i or 59.94p format is selected;

vertical phase of 75H when the 50i or 50p format is selected)

TRI:

Tri-level sync signal (vertical phase of 0H)
This can be selected when HD format signals are supplied.

Internal sync: For synchronization with an internal reference signal (INT). The REFOUT signal (black burst

signal) is output from the two reference connectors.

1

Press the [FUNC] switch to light its indicator, and then press the [SETUP] switch to display the SETUP

menu.

2

Turn [F1] to display the REF menu.

3

Turn [F], select the sync signal using the SYNC item, and press the [F4] switch (EXEC) to enter the

selection.
An asterisk ( ) appears at the left of the reference signal currently selected.

BBAD

TRI

INT

REF

5/15

SYNC

BBST

GL

EXEC

-

An asterisk ( ) appears at the GL item when operation is synchronized with the external or internal sync
signals.
A dash (–) appears at the GL item when operation is not synchronized with the external or internal sync
signals.