Maintenance, Temp and lamp indicators, Managing the indicated problems – Panasonic PT-AE4000U User Manual

Page 25: Nglish - 25, J temp indicator, J lamp indicator

Advertising
background image

E

NGLISH - 25

Maintenance

TEMP and LAMP Indicators

Managing the indicated problems

If a problem should occur with the projector, the

LAMP and/or TEMP

indicators will inform you. Manage the indicated problems as follows.

Confirm the status of all indicators and projector, and switch off

1.

the projector in proper way.

Find out the cause of the problem by status of the

2.

LAMP and/

or

TEMP indicators.

Follow the following instruction for each indication and solve

3.

the problem.

Turn on the projector in the correct way and confirm the

4.

indicator is not indicating a problem any longer.

Power

LAMP TEMP

J

TEMP indicator

Indicator

Illuminating red while projecting and the alert will be displayed.

Flashing red and the power button is turned off automatically.

When the

TEMP indicator is lit, the lamp might have darkened.

Adjustments can be performed but not all changes will be shown on the image.

Problem

The temperature inside and/or outside the projector is abnormally high.

Cause

The air intake and exhaust

ports are covered.

The room temperature is

too high.

The air filter is excessively

dirty and the ventilation is

poor.

The projector is located

at high elevations (above

1 400 - 2 700 m).

Remedy

Remove the object(s)

from the ventilation

openings or clear around

the projector.

Reinstall the projector in

a temperature controlled

place. See page 32.

Clean or replace the air

filter in the proper method.

See page 26.

Turn on the projector and

set the

HIGH ALTITUDE

MODE to ON.

See “INSTALLATION” of

the functional instructions

that is in the provided CD-

ROM.

J

LAMP indicator

Indicator

Illuminating red

Flashing red

Problem

LAMP RUNTIME has

reached 1 800 hours.

Lamp circuit failure, abnormal function or lamp unit is damaged.

Cause

The lamp unit will run out

soon and needs to be

replaced.

The power is turned on

again before the lamp unit

is cooled enough.

Lamp circuit failure,

abnormal function.

The lamp unit is damaged.

Remedy

See “Replacing the lamp

unit” on page 27.

Let the lamp unit cool

down and turn on the

power after 90 seconds.

Contact an Authorized

Service Center.

See “Replacing the lamp

unit” on page 27.

NOTE:

If no problem is found or the problem remains, do not turn on the projector. Instead contact an Authorized Service Center.