Test jacks – Paradyne 3160 User Manual

Page 119

Advertising
background image

Maintenance

4-17

3160-A2-GB21-80

March 1999

Test Jacks

For 2-port and 4-port DSU/CSUs, six test jacks are located on the front panel
(Figure 4-1). The Mon (Monitor) branch of the menu tree allows you to select
either EQPT (Equipment) or NET (Network).

The 2-port and 4-port DSU/CSU test jack functions are shown in

Figure 4-2

and

described in

Table 4-7

.

In

Out

In

Out

In

Out

NET

MON

EQPT

496-14808

Figure 4-1.

Test Jacks (Standalone DSU/CSU)

"

Procedure

To change the Mon (Monitor) selection in 2-port and 4-port DSU/CSUs:

1. From the top-level menu, press the

key until the Ctrl selection appears

on the screen.

2. Select Ctrl.

3. From the Control screen, press the

key until the Mon selection appears

on the screen.

4. Select Mon.

F1

Control:
Passwd Mon

F2

F3

5. From the Mon Jack screen, press F1 to select EQPT (the default), or press

F2 to select NET.

F1

Mon Jack: EQPT
EQPT

NET

F2

F3