28. Adjustment of the stop for the left needle position on Pfaff 1540

Requirement:

When all push buttons are switched off, the needle must be approx. 0.2 mm further left than the widest

zigzag stitch.

The needle must not touch the needle plate.

Check:

z

Set stitch width adjustment dial to "5".

z

Set needle position adjustment dial to "center".

z

Press the zigzag stitch button.

z

Rotate the handwheel until the needle moves downward on the left side and is at a position of roughly

1 mm above the needle plate (fig. 56).

z

Press the button for the buttonhole bartack.

The needle should now move approximately 0.2 mm to the left.

Adjustment:

z

Set stitch width adjustment dial to "5".

z

Set needle position adjustment dial to "center".

z

Press the zigzag stitch button.

z

Loosen screw 84 (fig. 38).

z

Push stop 85 to a position 0.2 mm from the crank 90.

z

Tighten screw 84.

Cross-check:

z

Press the zigzag stitch button and the button for the buttonhole bartack alternately and check whether

the needle moves by approx. 0.2 mm without touching the needle plate.