55. Changing the mains connections in foot control AE 010

Note:

When changing connections it is compulsory to use original PFAFF connection cables, as only these are

approved.

Removal:

z

Turn the foot control so that it is resting on pedal 175.

z

Insert a screwdriver with a wide blade on the side opposite to the cables (fig. 120).

z

Turn the screwdriver while removing pedal 175 upwards.

z

Carefully remove mains connection cables or machine cables 177 from the circuit board (fig. 120).

z

Loosen screw 178 or 179.

z

Remove mains lead cleat 180.

z

Remove mains connection cable or machine cable.

Refitting:

z

Insert new cable 177 through the bore.

z

Insert mains lead cleat 180 and secure with screw 173 or 174.

z

Connect mains connection cables or machine cables 177.

z

Refit pedal 175.

z

Use a screwdriver with a wide blade to press the pedal a little aside and insert it downwards.

z

Carry out a functional test.

z

Carry out an electrical safety test in accordance with VDE 0701 using testing appliance ABB Metrawatt

M 5013.