Users Manual Model 656/636

Electrical Trouble Shooting

45

Electrical Trouble Shooting

Power Up / Sign On / Communications

Problem

Probable Cause

Corrective Action

Machine fails to power up with no

light present in the AC power
switch.

1) Incorrect power amplitude.

1) Confirm that the AC entry is

configured for the line voltage
intended to be applied to the
machine. Failure to do so can
damage the machine's internal
power supply. Refer to the "Fuse
Configuration".

2) Lack of power to machine.

2) Check that both ends of the power

cord are plugged in securely.

2A) Confirm that the outlet the

machine is plugged into has power.

3) Missing or blown fuse(s)

3) Check that the fuse(s) located

inside the AC entry are present and
intact. Replace as needed. Refer to
the "Fuse Configuration".

Machine fails to power up with light

present in the AC power switch.

1) Unconnected cable / connector

inside machine.

1) Power off and remove the power

cord from the AC entry. Remove
the back cover and inspect the
cables and connectors to and from
the power supply. Refer to the
"Electrical System Schematic".

2) Thermal Control Board unplugged

from the Mother Board

2) Power off and remove the power

cord from the AC entry. Remove
the back cover and reseat the
Thermal Control Board.

Front panel displays no text or

nothing at all.

1) Front panel cable unplugged.

1) Power off and remove the power

cord from the AC entry. Remove
the back cover and inspect the
cable and connectors to and from
the front panel. Refer to the
"Electrical System Schematic".