Lc2h, Part names, Dimensions – Panasonic LC2H User Manual

Page 12: External dimensions, Panel cut out dimensions

Advertising
background image

LC2H

Part names

1. Front reset key
This key resets the count value. It does
not work when the lock switch is ON.
2. Mode key
Use to switch between each mode.
3. Setting key
Used to set digits of preset values or set
each mode.
4. Set key
Use to set preset values or to switch
between modes.
5. Lock switch
Disable the operation of the front panel
reset key and the mode key. With the lock
switch on,

is displayed for about

two seconds when the reset key or mode
switch is operated.
6. Count speed switch
Use this switch to switch the count speed
between 30 Hz and 5 kHz.

❇: Default setting when shipped.

Notes: 1. Make the switch setting before installing to panel.

2. Please turn the power off if you change the setting of the count speed switch when the power is on. The

setting will become valid when the power is turned back on.

5

Lock switch

(unit display 1)

6

Count speed switch

(unit display 2)

6

5

RESET

MODE

SET

COUNTER

LC2H

1

2

3

4

(Terminal block side)

(LCD side)

OFF

ON

(Terminal block side)

(LCD side)

5kHz

30Hz

Dimensions

• External dimensions

mm

inch

General tolerance:

±1.0

±.039

When installing the one-touch installation type model, make sure
that the installation spring does not pinch the rubber gasket.
To prevent the installation spring
from pinching the rubber gasket:
1. Set the rubber gasket on both
ends of the installation spring
(left and right).
2. Confirm that the installation
spring is not pinching the rubber
gasket, and then insert and fix the
installation spring in place from the
rear of the timer unit.

44.8

1.764

54.4

2.142

10.4

.409

44

1.732

5

.197

22

.866

7

.276

COUNTER

LC2H

RESET

MODE

SET

24

.945

48

1.890

• Panel cut out dimensions

The standard panel cut out is shown below.
Use the mounting bracket (ATH3803) and the rubber gasket (ATH3804).
(Only installation frame type)

• When installing repeatedly (sealed installation)
(Only installation frame type)

Notes: 1. Suitable installation panel thickness is 1 to 4.5 mm

0.39 to 0.177 inch

.

2. Waterproofing will be lost when installing repeatedly (sealed installation).

45

1.772

+0.5

0

+.020

0

22.2

.874

+0.5

0

+.020

0

60 min.

2.362 min.

22.2

.874

+0.5

0

+.020

0

A=(48

×n-2.5)

A=(1.890

×n-.098)

A

+1.0

0

+.039

0