Rop connector panel, Connections, System component connections – Panasonic AK-HRP931P User Manual

Page 16: Reference files, Calling reference files, Storing reference files, Connections reference files, Parts and their functions, 16 rop connector panel, Connections of the system components

Advertising
background image

16

ROP connector panel

RCP

CCU

PREVIEW

X

Y

Z

RCP connector

The remote control panel (RCP) is connected here.

Y

CCU connector

The camera control unit (CCU) is connected here.

X

Preview control connector [PREVIEW]

This is the output connector which is used for previewing.
When the joystick is pushed in, the contact information is
output.

Z

Connections

Reference files

Connections of the system components

1. Connect this panel by connecting its CCU connector to the

ROP connector on the rear panel of the CCU using the
dedicated ROP cable (optional accessory).

2. After having connected all the components, set the CCU’s

main power switch to ON, and then set the camera power
switch to ON.

<Notes>

When the camera is not connected, the functions which can
be controlled using this panel are limited to the CCU control
items.

Before disconnecting the ROP able, be certain to set CCU’s
camera power switch to OFF.

This function stores data in the files containing the user’s basic settings (user files) and calls the data from them. It is also possible
to call data from the file in which the initial camera settings were stored at the factory (factory file).

Calling reference files

1 Factory file

Press scene file switch 4 while holding down CALL. The file call is completed when the scene file switch 4 LED goes off.

2 User files

Press scene file switch 1, 2 or 3 while holding down CALL. The file call is completed when the scene file switch LED goes off.

Storing reference files

User files

When the camera is adjusted and set to the statuses which are to be stored and the scene file storage switch is pressed, the
LED of the switch flashes red. When scene file switch 1, 2 or 3 is now pressed while holding down CALL, the lamp of the
scene file storage switch lights up. Storage is completed when the lamp goes off.

ROP

RCP

CCU

PREVIEW

CCU

AK-HCU931P

AK-HRP931P

ROP cable

Parts and their functions