Introduction and Installation

Wiring schematic diagram

Note:

L

The Door Opener wiring schematic diagram is an example. Refer to the wiring instructions
provided with your Door Opener and PBX for details.

L

Refer to the technical data on page 38 when connecting to a Door Opener.

Power cable/wire type and distance

L

Power cable (between the monitor station and the AC adaptor):
Type: Ф1.2 Fire alarm cable 16 AWG
Distance: Maximum 30 m

L

Wire (between the monitor station and the door station):
Type: General cable CAT-3 24 AWG
Distance: Maximum 100 m
Loop resistance: 18.4

Ω or lower

L

Wire (between the monitor station and PBX):
Type: General cable CAT-3 24 AWG
Distance: Maximum 100 m

D1 D2

Door station

Monitor station

AC adaptor

Power cable

(Non polar)

(Non polar)

(Non polar)

D1
D2
P1
P2
S1
S2

PBX

Door (Door Opener)

Terminal box
(4-conductor wiring)

Power cord