Easytouch system start-up, Check electronics, Easytouch system test – Pentair EasyTouch 8 and 4 Pool and Spa Control System User Manual

Page 27

Advertising
background image

21

EasyTouch Load Center Installation Guide

EasyTouch System Start-Up

Perform the following start-up procedures to ensure that the EasyTouch load center is installed
correctly. If you need more detailed operating information, refer to the EasyTouch Pool and Spa
Control System User’s Guide (P/N 520584).

Before you power up the EasyTouch load center check the following:

Check Electronics

Check that the following plugs are seated correctly on the motherboard:

Relay connectors - FLTR PUMP - AUX1 - AUX7 (EasyTouch 8), AUX1 - AUX3

(EasyTouch 4)

Temperature sensors connectors WATER, SOLAR, AIR

Transformer wire harness (J1) attached to the motherboard.

Heater control connector ELEC HTR or two-wire screw terminal.

Refer to Summary Installation Steps (page 2) and EasyTouch System Wiring Diagrams, on page 23.

EasyTouch System Test

The following describes how to test the main control panel to activate the heater, valves and pumps.
Before testing the system, be sure that all pool and spa equipment has been properly installed and
connected to the EasyTouch load center.

Testing Valve Actuators and Filter Pump

Use the following steps to test the valve actuators (CVA24T) for proper rotation.

To test the valve actuators and pump:

1. Power up the EasyTouch load center.

2. Press the Mode button on the main control panel. The display shows “SERVICE”.

3. Press the Valve (V) button to select POOL.

4. Press the Filter Pump (F) button to activate the filter pump. Water will be removed from the

pool and returned to the pool.

4. Repeat steps 3 and 4 selecting Fill (Spillway) then Drain.

5. Set both valve actuators (CVA-24T) for suction and return. Use the toggle switch on the rear

of the CVA-24T to withdraw and return water from the pool.

Note: With the filter pump operating, if the water is not being removed and returned to the

pool, check that the valve actuator plugs are connected correctly on the motherboard.

Testing the auxiliary relays

Affix the auxiliary relay labels to the appropriate AUX buttons on the EasyTouch control panel to
identify the connected equipment.

Press the Mode button to enable “Service” pool mode. Press the Filter Pump button (LED

on) and each auxiliary (AUX) circuit button, the Heater and Solar buttons to verify the
functions. Press the Mode button twice to return the system to “AUTO” mode when done.