ELECTRICAL

Ground motor before connecting to electrical power supply! Failure to
ground pump motor can cause serious or fatal electrical shock hazard!

Do not ground to a gas supply line!

To avoid dangerous or fatal electrical shock, turn OFF power to motor
before working on electrical connections.

GFCI tripping indicates an electrical problem. If GFCI trips and will not
reset, have a qualified electrician inspect and repair electrical system.

Exactly match supply voltage to nameplate voltage (115 Volt or 230
Volt single phase only)! Incorrect voltage can cause fire or seriously

damage motor and voids warranty!

Grounding:

Install, ground, and wire motor according to local or National Electrical Code
requirements.
Permanently ground motor; use size and type wire required by code.
Ground connection must be made to green grounding terminal under motor
canopy or access plate (see Figure 1B).
Connect motor ground terminal to electrical service ground.
Install and bond pump according to local codes and ordinances; use bond-
ing lug on motor (see Figure 1A). Use solid copper conductor No. 8 AWG
(8.4mm

2

) or larger.

Wiring:

Pump must be permanently connected to circuit. Table I, Page 6, gives cor-
rect wire and circuit breaker sizes for the pump alone. If other lights or appli-
ances are also on the same circuit, be sure to add their amp loads to pump
amp load before figuring wire and circuit breaker sizes. (If unsure how to do
this or if this is confusing, consult a licensed electrician.) Use the load circuit
breaker as the master on-off switch.
Install a Ground Fault Circuit Interrupter (GFCI) in circuit; it will sense a
short-circuit to ground and disconnect power before it becomes dangerous
to pool users. For size of GFCI required and test procedures for GFCI, see
manufacturer’s instruction.
In case of power outage, check GFCI for tripping (which will prevent normal
pump operation). Reset if necessary.
NOTICE: If you do not use conduit when wiring motor, be sure to seal wire

opening on end of motor to prevent dirt, bugs, etc., from entering.

Hazardous voltage.
Can shock, burn,
or cause death.

Ground pump before
connecting to
power supply.

BONDING

LUG

MOTOR NAMEPLATE

GREEN

GROUND

SCREW

MOTOR

CANOPY

THROUGH

BOLTS

499 0993

Figure 1A: Typical ground screw and
bonding lug locations.

White

230
Volt
Lines

A

B

L2

L1

Blue

SINGLE

VOLTAGE

MOTORS

DUAL

VOLTAGE

MOTORS

A

B

L2

L1

White
w/Black
Tracer

Black

115
Volt
Lines

A

B

L2

L1

White
w/Black
Tracer

Black

230
Volt
Lines

Motor Terminal Board Connections

Figure 1B. Motor terminal block con-
nections.