5. Screw impeller onto shaft until it seats against shaft shoulder. Work

slinger over end of impeller sleeve so it rides on sleeve (Figure 6).

6. Remount front plate; using pattern, shown in Figure 7, torque bolts to 30

inch-lbs. (34.5 cm-kg). BE SURE to start with bolt in 3 o’clock position as
shown.

7. Reconnect unions; tighten hand tight only.

STORAGE/WINTERIZING

To prevent damage to components from fumes, store spa chemicals
away from pump and spa. If possible, store chemicals in another room.

Allowing pump to freeze will damage pump and void warranty!

Drain all water from pump and piping when expecting freezing temperatures
or when storing pump for a long time (see instructions below).

Keep motor dry and covered during storage.

To avoid condensation/corrosion problems, do not cover or wrap pump with
plastic.

For outdoor/unprotected pump installations:

1. Enclose entire system in a weatherproof enclosure.

2. To avoid corrosion damage, sllow ventilation; do not wrap system in

plastic.

Follow spa manufacturer’s directions for storage of spa.

Figure 6

Figure 7 – Torque Sequence

#1

#6

#2

#5

#3

#4

Start
Here