Voltage:

Voltage at motor must be not more than 10% above or below motor name-
plate rated voltage or motor may overheat, causing overload tripping and re-
duced component life. If voltage is less than 90% or more than 110% of
rated voltage when motor is running at full load, consult power company.

Values given in tables below are for PUMP MOTOR ONLY. If addi-
tional spa accessories are installed on pump motor circuit (heater,

blower, etc.), include their amperage draw when figuring wire and circuit
breaker sizes.

L2

B

A

L1

Lo

Hi

Timer Motor

Supply

Lo

Hi

Circuit

Protector

Remote

SPDT

Switch

Ground

(Green)

Common

Remote Switching For 2-Speed Pumps

Timer (optional)
Low Speed Only

Minimum switch and timer amp rating must equal Branch Fuse Rating
given in "Recommended Circuit Breaker Size and Wiring Data" table.

Branch

AWG (mm

2

) Wire Gauge Size

Full

Circuit

Dist in Ft. (M) - Service to Motor

Model

Motor

Load

Breaker

0-100

101-200

201-300

Temp

No.

HP

Volts

Amps

Amp Rating

(0-30)

(31-60)

(61-90)

Deg. C.

Single Speed Pumps:
JSACL-A

1/2

115

7.0

15

14 (2.0)

12 (3.0)

10 (5.5)

75

JSADL-2A

3/4

115

9.0

15

14 (2.0)

14 (2.0)

10 (5.5)

75

JSAEL-2A

1

115

12.0

15

14 (2.0)

10 (5.5)

8 (8.4)

75

JSAFL-A

1-1/2

115/230

16.4/8.2

25/15

10/14 (5.5/2.0)

8/14 (8.4/2.0)

6/12 (14/3.0)

75

JSAEFL-A

1-1/2

115/230

14.4/7.2

20/15

12/14 (3.02.0)

8/14 (8.4/2.0)

6/14 (14/2.0)

75

JSADL-230A

3/4

230

4.8

15

14 (2.0)

14 (2.0)

14 (2.0)

75

JSAEL-230A

1

230

6.1

15

14 (2.0)

14 (2.0)

14 (2.0)

75

Two Speed Pumps:
JSAYDL-A

3/4-1/8

115

9.0/2.7

15

14 (2.0)

12 (3.0)

10 (5.5)

75

JSAYDL-LA

3/4-1/8

115

9.0/2.7

15

14 (2.0)

12 (3.0)

10 (5.5)

75

JSAYEL-A

1-1/6

115

11.7/3.4

15

14 (2.0)

10 (5.5)

8 (8.4)

75

JSAYEL-LA

1-1/6

115

12.0/3.3

15

14 (2.0)

10 (5.5)

8 (8.4)

75

JSAYFL-LA

1

1

¼

2

- 1/6

115

16.6/3.6

25

10 (5.5)

8 (8.4)

6 (14)

75

JSAYDL-230A

3/4-1/8

230

4.7/1.4

15

14 (2.0)

14 (2.0)

14 (2.0)

75

JSAYEL-230A

1-1/6

230

6.3/1.8

15

14 (2.0)

14 (2.0)

14 (2.0)

75

JSAYFL-230A

1

1

¼

2

- 1/6

230

8.1/1.7

15

14 (2.0)

14 (2.0)

12 (3.0)

75

JSAYDL-220A

3/4-1/8

220

5.4/1.4

15

14 (2.0)

14 (2.0)

14 (2.0)

75

JSAYEL-220A

1-1/6

220

6.3/1.8

15

14 (2.0)

14 (2.0)

14 (2.0)

75

TABLE I - RECOMMENDED CIRCUIT BREAKER SIZE AND WIRING DATA FOR 60 Hz MOTORS