220 vac basic system wiring – Pentair IC20 User Manual

Page 43

Advertising
background image

35

IntelliChlor Electronic Chlorine Generator Installation and User’s Guide

System Specifications - 110 VAC and 220 VAC Wiring

Circuit Protection: Two-pole 20 AMP device at the electrical panel.

IntelliChlor Model IC20

Input: 95-130 VAC, 50/60 Hz, 220 Watts (2 AMP) or 220-240 VAC, 50/60 Hz, 220 Watts (1 AMP).

Output: 22-39 VDC @ 6 AMPS maximum from the Power Center.

Chlorine: 0.70 lb. / 24 hour of continuous pump run time (317 gm / 24 Hour).

Water flow: 20 gallons per minute minimum. 105 gallons per minute maximum. Maximum pressure: 75 psi

IntelliChlor Model IC40

Input: 95-130 VAC, 50/60 Hz, 220 Watts (2 AMP) or 220-240 VAC, 50/60 Hz, 220 Watts (1 AMP).

Output: 22-39 VDC @ 6 AMPS maximum from the Power Center.

Chlorine: 1.40 lb. / 24 Hour of continuous pump run time (635 gm / 24 Hour).

Water flow: 20 gallons per minute minimum. 105 gallons per minute maximum. Maximum pressure: 75 psi.

IMPORTANT: When using IntelliChlor with an IntelliTouch system, it is recommended to wire
the Power Center to the pump side of the relay located in the IntelliTouch Load Center. This
method does not require a ground fault circuit-interrupter (GFCI) to protect the circuit.

220 VAC Basic System Wiring

Advertising
This manual is related to the following products: