Taking a reading – Panasonic EW3153 User Manual

Page 22

Advertising
background image

1

English



English

Taking a Reading

(continued)

Irregular pulse function

If the pulse rate varies by more than ±5% from the average while a

measurement is being taken, when measurement is completed the

mark will be displayed.

The

mark will be lit after approx. 6 seconds of blinking when

the measurement is completed.

If the

mark is lit, please take the measurement again.

In some cases, if the pulse rate fluctuates greatly while a measurement

is being taken, it may be impossible to obtain an accurate reading.

(Flashes.)

(Is lit.)

If you save a reading where an irregular pulse was recorded, the

mark will be displayed when you recall that reading.

If the

mark is displayed an irregular pulse rate is detected,

not necessarily due to atrial fibrillation. However, if this mark continues

to be displayed in subsequent readings, please consult with your

physician.

* This function is designed to act as a guide to help you to obtain

accurate readings (Please see pages 15–18).

* If the

mark is frequently displayed, please consult a health

professional for your health condition.

Don’t try to interpret readings or attempt to treat any condition
yourself.
Always follow the guidance of a health professional.

Alarm function signals high blood pressure

Blood pressure values for both systolic and diastolic readings are

determined and indicated via mark in the display as being within normal

or hypertensive ranges based on definitions and classification of blood

pressure levels by the JNC 7. Moreover, when blood pressure is in the high

range, the reading displayed on screen flashes on and off to alert user.

According to JNC 7 Classification, values consistently in excess of

140 mmH

g (Sys.) and/or 90 mmHg (Dia.) are considered to constitute high

blood pressure.

(mmH

g

)

Systolic

mark

positions

120 140

80

90

(mmH

g

)

Diastolic

Blood pressure
sign

Orange

Yellow

Green

Hypertension
(Stage 1, Stage 2)

Prehypertension

Normal

Blood pressure readings will flash for approx. 6 seconds

when in the high blood pressure range.

Systolic blood pressure: 140 mmH

g and over

Diastolic blood pressure: 90 mmH

g and over

(Only when measurement is complete)

When an Error Occurs During Measurement

A

will appear on the display to indicate that measurement

was unsuccessful and should be performed again.

Before performing another measurement, always press the

On/Off and Start button to turn off the unit and make sure to

allow a rest period of 4 to 5 minutes before starting again.

Please consult your doctor without delay if the blood

pressure indicator repeatedly displays to elevated blood

pressure values.