Proxy server commands
Use the following parameters when programming the configuration 
files. See the sample configuration files following this table for more 
detailed information. 
Parameter
Value
Description
Notes
PROXYn_ADDR
xxx.xxx.xxx.xxx:ppp
p 
 
or 
Proxy address. One 
proxy address is 
required but additional 
proxy addresses may 
be used
to register
secondary line 
appearances. 
n = 1, 2, 3
xxx.xxx.xxx.xxx = IP address
pppp = port (optional, 5060 is 
the default) 
proxyname:pppp
proxyname = proxy server 
name (DHCP only) 
PROXYn_DOMAIN Domain
name Domain served by this
proxy server.
n = 1, 2, 3
DOMAIN = [example: 
spectralink.com] 
Can be omitted if a specific 
proxy domain name is not 
defined at the proxy server. If 
omitted, defaults to the IP 
address of the proxy server 
(see above) 
PROXYn_TYPE Asterisk
SER
Specify the 
manufacturer of each 
defined proxy server. 
Used by the handset to 
perform proxy-specific actions 
based on known behavior for 
specific proxy types. Omit this 
parameter if the value is not
Asterisk or SER. 
PROXYn_KEYPRESS_2
833 
*enable 
disable 
*default (in example 
file) 
Controls generation of 
in-stream RFC2833 
formatted key press 
events. Match what is 
required by your PBX. 
See RFC2833. See 
config file example for 
more information. 
n = 1, 2, 3
Must be disabled for OAI.
PROXYn_KEYPRESS_I
NFO 
enable 
disable 
Controls generation of 
SIP INFO requests to 
the SIP server for 
keypress events.
Normally enabled. 
n = 1, 2, 3
Must be enabled for OAI.
PROXYn_REREG_SEC
S 
35 seconds to 
3600 seconds 
The requested 
expiration interval in 
REGISTER request 
n = 1, 2, 3
If the server has a lower 
maximum setting or a higher