Pentair D.E. Cartridge Style Filter User Manual

Page 9

Advertising
background image

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Rev. F 6/15/06

9

P/N 99101200

SECTION VI.

CHECK VALVE INSTALLATION INSTRUCTIONS

WARNING

THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF

THE CIRCULATING SYSTEM (e.g. LOCK RING, PUMP, FILTER VALVES,

ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME

PRESSURIZED. PRESSURIZED AIR CAN CAUSE THE LID TO BE BLOWN

OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY

DAMAGE.

TO AVOID THIS POTENTIAL HAZARD, FOLLOW THESE

INSTRUCTIONS.

15. BEFORE REPOSITIONING VALVES AND BEFORE BEGINNING THE

ASSEMBLY, DISASSEMBLY, OR ADJUSTMENT OF THE LOCK RING OR

ANY OTHER SERVICE OF THE CIRCULATING SYSTEM: (A) TURN THE

PUMP OFF AND SHUT OFF ANY AUTOMATIC CONTROLS TO ENSURE

THE SYSTEM IS NOT INADVERTANTLY STARTED DURING THE

SERVICING; (B) OPEN AIR RELIEF VALVE; (C) WAIT UNTIL ALL

PRESSURE IS RELIEVED.

16. WHENEVER INSTALLING THE FILTER LOCK RING FOLLOW THE

CLEANING FILTER INSTRUCTIONS EXACTLY.

17. ONCE SERVICE OF THE CIRCULATING SYSTEM IS COMPLETE

FOLLOW THE INITIAL START SYSTEM RESTART INSTRUCTIONS

EXACTLY.

18. MAINTAIN CIRCULATION SYSTEM PROPERLY. REPLACE WORN OR

DAMAGED PARTS IMMEDIATELY (e.g., lock ring, pressure gauge, relief

valve, o-rings, etc).

19.

BE SURE THAT THE FILTER IS PROPERLY MOUNTED AND

POSITIONED ACCORDING TO THE INSTRUCTIONS PROVIDED.

1. Turn the pump off, shut off any automatic controls to assure that the system is not

inadvertently started during servicing.

2. Open the High Flow

TM

manual relief valve.

3. Plug the suction line by inserting a rag into the skimmer port, or if equipped with a valve

close it at this time to prevent water from siphoning from the pool during servicing.

4. If possible, plug the return line to prevent siphoning. If this cannot be done, disconnect the

union fitting from the outlet port of the filter and quickly place the return hose into the

pool.

5. Remove the drain cap to empty the water from the filter.
6. Insert the Check Valve into the outlet port approximately

¾” to 1” deep making sure the rubber diaphragm is

facing outward (toward you), see Diagram 1.

7. Reconnect the return hose to the outlet port and tighten

the union fitting.

8. Replace the drain cap.
9. Remove the rag from the skimmer or open the valve on

the suction line.

10. If the return line was plugged, unplug it at this time.

Rev. F 6/15/06

9

P/N 99101200

Advertising