Starting a telnet session – PSC FALCON 315 User Manual

Page 21

Advertising
background image

Quick

Start

Starting a Telnet Session

At the Twin Client main menu on the terminal, press any key to establish the connection.
Until the terminal has been authorized, the following screen is displayed.

RECOVERABLE ERROR
Terminal not
Authorized for
Twin Client

Keypress to Continue

It is not necessary to authorize the terminal at this time, so press any key to continue. The
terminal will establish a connection with the host system and start emulation. If the
terminal fails to connect to the host, refer to the following tables.

Failure Cause

Corrective Action

Incorrect Host IP address

Correct the Host List address on the terminal. Refer to
Terminal Setup Using Twin Client Menus.

Incorrect netmask value

Access the Edit Functions menu. Correct the netmask
value. Refer to Terminal Setup Using Twin Client Menus.

Error Indication

Possible Cause

Corrective Action

NOT Associated

Invalid NETID

Run current radio setup program and
set NETID to match the access point.
See Terminal Setup Using Twin Client
Menus
.

No AirLoad
Manager Found.

AirLoad Manager not
active, or not installed
on the LAN segment.

Ensure that the PC with Twin Client
Manager is on the same segment and
that the PC is operating. If the PC is
not on the same segment, enter the
address of the PC in response to the
terminal prompt.

Manager not Active

Previously identified
AirLoad Manager is no
longer found.

Same as above

Unable to open
connection

IP stack on terminal
failed to load.

Reload Program Files and reboot.

Timeout waiting for
data

Transient
communications
failure

Reboot terminal. If problem persists,
check the RFSYNC.log in the
PowerNetTN directory.

Download aborted

Socket closed during
download

Ensure that PC is operating. Reboot
terminal and retry.

Manager inactive

PC not operating

Restart the Airload PC server.

After a Telnet session has been successfully established, the terminal will remain in
session for a maximum of 30 minutes at a time until it has been authorized. Once
authorized, there is no software restriction on the session time. The instructions for
authorizing the terminal are presented in Authorizing PowerNet.